SQ4-C11 Leak controller – Panasonic (SQ-4) – Supply voltage(DC) 24V – For up to 4 sensing devices
SQ4-C11
Specifications SQ4-C11
Item |
Performance characteristics |
---|---|
Sensing range | n/a |
Supply voltage | 24 V DC+10-15 % Ripple P-P 10 % or less |
Current consumption | 200 mA or less |
Leakage detection output(Abnormal leakage detection, Safety output) | n/a |
Leakage detection output(Abnormal leakage detection, Safety output):Response time | n/a |
Leakage detection output(Abnormal leakage detection, Safety output):Output operation | n/a |
Initial leakage detection output (Initial leakage, Non-safety output) | n/a |
Initial leakage detection output (Initial leakage, Non-safety output):Response time | n/a |
Initial leakage detection output (Initial leakage, Non-safety output):Output operation | n/a |
Protection | IP20 (IEC) (However, it should be in IP54 protection structure of control panel) |
Ambient temperature | -10 to +55 degrees +14 to +48.2 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -10 to +55 degrees +14 to +48.2 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Emitting element | n/a |
Material | Main unit case: PC / ABS (alloy) |
Cable | n/a |
Weight | Net weight: 170 g approx Gross weight: 440 g approx |
More detail |
|
More Product |
Applicable standards:International standard
ISO 13849-1 (Category 4, PLe), IEC 60947-5-2, IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3)Applicable standards:JapanJIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
Applicable standards:Europe (EU)
EN 60947-5-2, EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3)
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
Applicable standards:South Korea
S1-G-1-2009, S2-W-5-2009Applicable standards:SEMIConforming to SEMI-S2-0310aControl outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switch method)
[Selecting PNP output]
– Maximum source current: 200 mA
– Applied voltage: Same as power voltage (between control output to +V)
– Residual voltage: 2.5 V or less (at 200 mA source current)
[Selecting NPN output]
– Maximum sink current: 200 mA
– Applied voltage: Same as power voltage (between control output to 0 V)
– Residual voltage: 2.0 V or less (at 200 mA sink current)Control output(OSSD 1, OSSD 2):Response time20 ms or less (excluding the response time of the sensor)Control outputs (OSSD 1, OSSD 2):Operation modeON when inntial detection, OFF when detection leakage or wrong installation