Search
Search

CIMR-VT4A0018FAA

คำอธิบาย

CIMR-VT4A0018FAA

Specifications

Application of Inverter Yaskawa V1000 ND: Fans, Pumps, HVAC
HD:Conveyor,Packaging, Food & Beverage, Auto shutter, Compressor, Chain Block Hoist, Commercial Washing Machine…
Power supply 3P 380 to 480Vac(− 15% to +10%), 50/60 Hz(± 5%)
Rated capacity 5.5kw
Rated current 18A
Output frequency range 0.01 to 400 Hz
Starting Torque 200%/0.5Hz (assumes Heavy Duty rating IM of 3.7 kW or less using Open Loop Vector Control)

50 % / 6 Hz (assumes PM Open Loop Vector Control)

Overload current rating ND Rating: 120 % of rated output current for 60 s, HD Rating: 150 % of rated output current for 60 s (Derating may be required for repetitive loads )
Control Method Open Loop Vector Control, V/f Control, PM Open Loop Vector Control (for SPM and IPM motors)
Braking unit All models are equipped with a braking transistor for even more powerful braking options by just adding a braking resistor.
Input Multi-function digital input,Main frequency reference input,Hardwire baseblock
Ouput Multi-function digital output, Multi-function photocoupler output, Monitor output
Protection Function Motor Protection, Momentary Overcurrent Protection, Overload Protection, Overvoltage Protection, Undervoltage Protection, Momentary Power Loss Ride -Thru, Heatsink Overheat Protection, Braking Resistance Overheat Protection, Stall Prevention, Ground Fault Protection: Protection by electronic circuit
Main Control Functions Momentary power loss ride- thru, Speed search, Overtorque detection, Torque limit, 17- step speed ( max ),Accel/decel time switch, S- curve accel/decel, 3 – wire sequence, Auto- tuning (rotational, stationary tuningfor resistance between lines), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation,Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start andstop,Overexcitation braking, High slip braking, PID control (with sleep function), Energy saving control, MEMOBUScomm. (RS-485 /422 max, 115 .2 kbps), Fault restart, Application presets, DriveWorksEZ (customized function ),Removable terminal block with parameter backup function…
Communication RS-422 /485 (MEMOBUS/Modbus at 115 .2 kbps) standard on all models.
Option cards available for all major serial networks used across the globe : PROFIBUS-DP, DeviceNet, CC-Link,CompoNet,CANopen, LONWORKS, MECHATROLINK-2, MECHATROLINK-3.
Peripheral Devices and Options LCD Operator, AC Reactor, DC Reactor, Braking Resistor, noise filter…
Speed Reference Card, Communications Option Card, Monitor Option Card, PG Speed Controller Card
Degree of protection NEMA1