คำอธิบาย
CIMR-VT4A0018FAA
Specifications
Application of Inverter Yaskawa V1000 | ND: Fans, Pumps, HVAC HD:Conveyor,Packaging, Food & Beverage, Auto shutter, Compressor, Chain Block Hoist, Commercial Washing Machine… |
Power supply | 3P 380 to 480Vac(− 15% to +10%), 50/60 Hz(± 5%) |
Rated capacity | 5.5kw |
Rated current | 18A |
Output frequency range | 0.01 to 400 Hz |
Starting Torque | 200%/0.5Hz (assumes Heavy Duty rating IM of 3.7 kW or less using Open Loop Vector Control)
50 % / 6 Hz (assumes PM Open Loop Vector Control) |
Overload current rating | ND Rating: 120 % of rated output current for 60 s, HD Rating: 150 % of rated output current for 60 s (Derating may be required for repetitive loads ) |
Control Method | Open Loop Vector Control, V/f Control, PM Open Loop Vector Control (for SPM and IPM motors) |
Braking unit | All models are equipped with a braking transistor for even more powerful braking options by just adding a braking resistor. |
Input | Multi-function digital input,Main frequency reference input,Hardwire baseblock |
Ouput | Multi-function digital output, Multi-function photocoupler output, Monitor output |
Protection Function | Motor Protection, Momentary Overcurrent Protection, Overload Protection, Overvoltage Protection, Undervoltage Protection, Momentary Power Loss Ride -Thru, Heatsink Overheat Protection, Braking Resistance Overheat Protection, Stall Prevention, Ground Fault Protection: Protection by electronic circuit |
Main Control Functions | Momentary power loss ride- thru, Speed search, Overtorque detection, Torque limit, 17- step speed ( max ),Accel/decel time switch, S- curve accel/decel, 3 – wire sequence, Auto- tuning (rotational, stationary tuningfor resistance between lines), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation,Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start andstop,Overexcitation braking, High slip braking, PID control (with sleep function), Energy saving control, MEMOBUScomm. (RS-485 /422 max, 115 .2 kbps), Fault restart, Application presets, DriveWorksEZ (customized function ),Removable terminal block with parameter backup function… |
Communication | RS-422 /485 (MEMOBUS/Modbus at 115 .2 kbps) standard on all models. Option cards available for all major serial networks used across the globe : PROFIBUS-DP, DeviceNet, CC-Link,CompoNet,CANopen, LONWORKS, MECHATROLINK-2, MECHATROLINK-3. |
Peripheral Devices and Options | LCD Operator, AC Reactor, DC Reactor, Braking Resistor, noise filter… Speed Reference Card, Communications Option Card, Monitor Option Card, PG Speed Controller Card |
Degree of protection | NEMA1 |